This entry includes the layout of the Gartech Glue Pump Solenoid Kit for assembly or replacement.
The Gartech Glue Pump Solenoid Kit no. 67165-2 will fit the ARO 666053-344C 1/2″ Diaphragm Pump supplied for use on the Gartech Glue System.
Please note: The (134) bolts will need to be completely removed from the pump before the stock plug can be removed and before the 93909 plug with 59756-4 push fitting can be inserted into the bottom of the 135 valve block.
The 94640 plug can be purchased individually from Gartech.
Repairs should never be performed while the glue pump is in service. Be certain to power down the Gartech Glue System and obey your facility’s safety requirements before attempting to service any component or subcomponent.